Melt Metal, Make Masterpieces
Equip yourself with the best gear to shape metal into masterpieces, showcasing your expert craftsmanship.
You’re attempting to view exclusive content only for members in the __tier_name__.
Already have an account? Sign in
You’re attempting to view exclusive content only for members in the __tier_name__.
Already have an account? Sign in
You’re attempting to view exclusive content only for members in the __tier_name__.
Already have an account? Sign in
You’re attempting to view exclusive content only for members in the __tier_name__.
Already have an account? Sign in
SKU:ED030631
Brand:Lincoln Electric
SuperArc® L-56® is Lincoln Electric's premium copper coated MIG wire and an excellent choice for welding on metals with a medium to high presence of millscale.
Enhance Your Gear With Accessories
Lincoln SuperArc® L-56® .030 MIG Welding Wire - 2 lb Spool (ED030631)
Classification | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %V | %Total Cu |
---|---|---|---|---|---|---|---|---|---|---|
ER70S-6 Requirement | 0.06 - 0.15 | 0.15 max. | 1.40 - 1.85 | 0.15 max. | 0.15 max. | 0.025 max. | 0.035 max. | 0.80 - 1.15 | 0.03 max. | 0.50 max. |
Typical Result | 0.07-0.10 | 0.01-0.05 | 1.41-1.58 | 0.01 max. | 0.03 max. | 0.003-0.013 | 0.013 max. | 0.80-0.98 | 0.005 max. | 0.13-0.29 |
Classification | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %V | %Total Cu |
---|---|---|---|---|---|---|---|---|---|---|
ER70S-6 Requirement | 0.06 - 0.15 | 0.15 max. | 1.40 - 1.85 | 0.15 max. | 0.15 max. | 0.025 max. | 0.035 max. | 0.80 - 1.15 | 0.03 max. | 0.50 max. |
Typical Result | 0.07-0.10 | 0.01-0.05 | 1.41-1.58 | 0.01 max. | 0.03 max. | 0.003-0.013 | 0.013 max. | 0.80-0.98 | 0.005 max. | 0.13-0.29 |
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F) |
---|---|---|---|---|---|---|---|
ER70S-6 Requirement | 100% CO2 | DC+ | 400 (58) min. | 480 (70) min. | 22 min. | 27 (20) min. | |
Typical Result, As-welded | 100% CO2 | DC+ | 420 (61) | 530-570 (77-82) | 25 | 43-121 (32-89) | |
Typical Result, As-welded | 75% Ar, 25% CO2 | DC+ | 430 (62) | 530-600 (77-86) | 23 | 62-182 (46-135) | 42-156 (31-115) |
Typical Result, As-welded | 90% Ar, 10% CO2 | DC+ | 490 (71) | 600 (87) | 24 | 87-109 (64-80) |
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F) |
---|---|---|---|---|---|---|---|
ER70S-6 Requirement | 100% CO2 | DC+ | 400 (58) min. | 480 (70) min. | 22 min. | 27 (20) min. | |
Typical Result, As-welded | 100% CO2 | DC+ | 420 (61) | 530-570 (77-82) | 25 | 43-121 (32-89) | |
Typical Result, As-welded | 75% Ar, 25% CO2 | DC+ | 430 (62) | 530-600 (77-86) | 23 | 62-182 (46-135) | 42-156 (31-115) |
Typical Result, As-welded | 90% Ar, 10% CO2 | DC+ | 490 (71) | 600 (87) | 24 | 87-109 (64-80) |
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.18 | ER70S-6 |
ABS | ABS - Part 2 | 3YSA H5 |
CWB | CSA W48 | B-G 49A 3 C1 S6 (B-G 49A 3 C G6) |
DNV-GL | DNV - 2.9 | III YMS H5 |
DB | ISO 14341-A | G 42 3 C1 3Si1, G 46 4 M21 3Si1 |
LR | LR - Chapter 11 | 3YS H5 |
MIL | MIL-E-23765/1D | MIL-70S-6 |
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.18 | ER70S-6 |
ABS | ABS - Part 2 | 3YSA H5 |
CWB | CSA W48 | B-G 49A 3 C1 S6 (B-G 49A 3 C G6) |
DNV-GL | DNV - 2.9 | III YMS H5 |
DB | ISO 14341-A | G 42 3 C1 3Si1, G 46 4 M21 3Si1 |
LR | LR - Chapter 11 | 3YS H5 |
MIL | MIL-E-23765/1D | MIL-70S-6 |